Hello Reader!
Welcome to the blog page of Aurobindo Eye Care And Health Centre, one of the best eye clinic in Kolkata.
Myopia, commonly known as nearsightedness, is a growing global concern, affecting children and adults alike. With the increasing prevalence of myopia, early diagnosis and effective myopia management strategies have become essential to prevent its progression and associated complications. Two critical assessments in this process are biometry and cycloplegic refraction. But how necessary are these tests for effective myopia management? Let’s explore their significance in detail.

Understanding Myopia and Its Progression
Myopia occurs when the eyeball is too long or the cornea is excessively curved, causing light to focus in front of the retina instead of on it. This results in blurry distance vision. If left unmanaged, progressive myopia can lead to severe eye disorders like retinal detachment, glaucoma, and macular degeneration.
Eye specialists rely on accurate diagnostic methods such as biometry and cycloplegic refraction to ensure proper myopia management.
What Is Cycloplegic Refraction and Why Is It Essential?
Definition of Cycloplegic Refraction
Cycloplegic refraction is a specialized test used to measure the accurate refractive error of the eye by temporarily paralyzing the eye’s focusing muscles using cycloplegic eye drops. This process prevents the natural accommodative effort of the eye, allowing the ophthalmologist to determine the true prescription without interference from the eyeâs focusing ability.
Importance of Cycloplegic Refraction in Myopia Management
- Accurate Diagnosis: Regular refraction tests can sometimes underestimate myopia in children due to the overactive focusing ability of young eyes. Cycloplegic refraction eliminates this error and provides an exact measurement of the refractive power.
- Differentiation Between Pseudo and True Myopia: Some cases of near vision strain may mimic myopia. Cycloplegic refraction helps differentiate between pseudo-myopia (temporary focusing issues) and true myopia.
- Effective Treatment Planning: By obtaining an accurate prescription, ophthalmologists can decide on the best interventions, including spectacles, orthokeratology, or atropine therapy for myopia management.

The Role of Biometry in Myopia Management
What Is Biometry?
Biometry is a precise measurement of the eye’s anatomical structures, including the axial length (AL), corneal curvature, and anterior chamber depth. This measurement is particularly crucial for tracking myopia management progress over time.
Why Is Biometry Important in Myopia Control?
- Predicting Myopia Progression: The axial length of the eye is a strong indicator of myopia progression. Monitoring axial length changes with biometry allows ophthalmologists to assess whether the current myopia management strategies are effective.
- Guiding Treatment Decisions: Certain myopia control treatments, such as low-dose atropine and orthokeratology, aim to slow axial length growth. Biometry helps measure treatment effectiveness.
- Reducing Future Risks: Longer axial lengths are associated with a higher risk of serious eye conditions like myopic maculopathy and retinal detachment. Regular biometry screenings allow for timely intervention.
The Combination of Biometry & Cycloplegic Refraction in Myopia Management
For effective myopia management, combining cycloplegic refraction and biometry is essential. While cycloplegic refraction ensures an accurate prescription, biometry helps track structural changes in the eye. This combination allows eye specialists to:
- Identify rapid myopia progression early.
- Implement personalized myopia management strategies.
- Prevent severe ocular complications associated with high myopia.

What are the benefits of using the Myopia Master for biometric measurements?
The Myopia Master offers numerous benefits for biometric measurements, making it an essential tool for modern myopia management. Below are the key advantages:
1. All-in-One Device
The Myopia Master combines three critical measurementsârefraction, axial length, and keratometryâinto a single device. Previously, these measurements required multiple instruments, which was time-consuming and less efficient. With its integrated approach, the Myopia Master simplifies the process of diagnosing and managing myopia.
2. Fast and Contactless Measurements
The device performs measurements quickly, typically within two minutes, and in a completely contactless manner. This makes it painless and highly patient-friendly, particularly for children who may otherwise be apprehensive about eye exams.
3. Axial Length as the Gold Standard
Axial length measurement is a critical parameter in myopia management because it provides a reliable indicator of myopia progression, independent of accommodation. The Myopia Master ensures highly accurate axial length readings, allowing practitioners to detect early changes in eye growth and intervene promptly.
4. Enhanced Software for Myopia Management
The Myopia Master includes exclusive software that supports clinical decision-making. Its features include:
- Risk factor analysis using patient questionnaires
- Age-adjusted growth curves for axial length
- Customized myopia reports with color-coded illustrations for better patient education
- Tools to assess treatment efficacy through the Growth Control Module.
5. Reliable and Reproducible Results
The device ensures consistent results with minimal variability. For example, repeated axial length measurements have a standard deviation of about 0.02 mm, equivalent to a refractive error change of only 0.05 diopters. This level of precision is crucial for tracking myopia progression accurately over time.
6. Improved Patient Communication
The Myopia Master generates detailed yet easy-to-understand reports that can be shared with patients and their families. These reports not only explain the findings but also recommend actionable steps for myopia management, fostering better understanding and compliance.
7. Early Detection and Prevention
By combining multiple parameters into one streamlined process, the Myopia Master enables early detection of myopia and its progression. Early intervention is vital to reduce the risk of complications such as retinal detachment or macular degeneration later in life.
8. Cost-Efficiency for Clinics
For eye care professionals, investing in the Myopia Master eliminates the need to purchase multiple devices separately. Additionally, its comprehensive software reduces the time spent on data interpretation and patient communication, improving workflow efficiency.
9. Customization for Individual Needs
The device offers advanced modules like the GRAS (Gullstrand Refractive Analysis System), which compares individual optical components with age-adjusted norms. This feature allows practitioners to tailor treatments based on each patientâs unique ocular anatomy.
Also Read: How to Research for the Best Eye Clinic in Kolkata?

Are there any risks associated with cycloplegic refraction in pediatric patients?
Cycloplegic refraction is a crucial diagnostic tool in pediatric ophthalmology, but like any medical procedure, it carries some risks and side effects, particularly related to the use of cycloplegic agents. Here are some of the risks associated with cycloplegic refraction in pediatric patients:
Risks and Side Effects of Cycloplegic Agents
- Atropine Side Effects: Atropine, a commonly used cycloplegic agent, can cause side effects such as flushing, tachycardia, fever, and delirium, especially in younger children. It has a longer duration of action, which can last from 3 to 12 days.
- Cyclopentolate Side Effects: Cyclopentolate is another frequently used agent. While generally safer than atropine, it can still cause mild side effects like blurred vision, photophobia, and redness. Cyclopentolate toxicity is a concern, particularly in infants, which is why lower concentrations (0.5%) are recommended for this age group.
- Photophobia and Blurred Vision: All cycloplegic agents cause temporary photophobia and blurred vision due to pupil dilation and accommodation paralysis. This can be distressing for children and may require protective measures like sunglasses.
- Risk of Misdiagnosis: While cycloplegic refraction is the gold standard for accurate diagnosis, improper use or inadequate cycloplegia can lead to misdiagnosis of refractive errors.
- Legislative Restrictions: In some regions, the use of cycloplegic agents is restricted to medical doctors, limiting access to accurate refraction in non-medical settings.
Precautions and Recommendations
- Conservative Approach: The American Optometric Association recommends using the lowest effective concentration of cycloplegic agents to minimize side.
- Monitoring and Management: Healthcare providers should be aware of potential side effects and be prepared to manage them appropriately.
- Patient Education: Parents should be informed about the temporary nature of side effects and the importance of cycloplegic refraction for accurate diagnosis
How does the repeatability of measurements change with and without cycloplegia?
The repeatability of measurements changes significantly with and without cycloplegia, particularly in the context of refractive error and biometric evaluations. Cycloplegia improves measurement precision by relaxing the ciliary muscle and eliminating accommodation, which is especially beneficial in pediatric patients. Below are the key findings regarding how cycloplegia affects repeatability:
1. Spherical Equivalent (SE) Repeatability
- Without Cycloplegia: SE measurements are less precise due to active accommodation. Test-retest repeatability (TRT) for SE is approximately 0.65 diopters (D), which exceeds the clinically significant threshold of 0.25 D.
- With Cycloplegia: Cycloplegia significantly enhances SE repeatability, reducing TRT to 0.31 Dâmaking measurements 2.5 times more precise compared to non-cycloplegic conditions.
2. Axial Length (AL) Repeatability
- Without Cycloplegia: AL measurements are relatively stable even without cycloplegia, but the TRT is slightly higher at 0.14 mm.
- With Cycloplegia: Cycloplegia improves AL repeatability marginally, reducing TRT to 0.09 mm, emphasizing its role in enhancing measurement consistency.
3. Keratometry (Km) Repeatability
- Without Cycloplegia: Keratometry measurements show good repeatability under non-cycloplegic conditions, with a TRT of 0.25 D.
- With Cycloplegia: Cycloplegia does not significantly affect keratometry repeatability, as the TRT remains similar at 0.27 D.
4. Agreement Between Pre- and Post-Cycloplegic Measurements
Cycloplegia causes a hyperopic shift in SE measurements:
- SE becomes more positive by +0.79 D on average.
- Myopic eyes show a mean difference of +0.31 D, while hyperopic eyes differ by +1.57 D.
This shift highlights the importance of cycloplegia for accurate refractive error assessment.
5. Peripheral Refraction Repeatability
Cycloplegia improves peripheral refraction repeatability by enlarging the pupil size (up to 6 mm) and relaxing the lens, ensuring consistent measurements across different quadrants. Without cycloplegia, peripheral refraction tends to have lower repeatability due to accommodation variability.
Can non-cycloplegic refraction be effective for myopia management in all cases?
Non-cycloplegic refraction can be effective for myopia management in certain cases, but it is not universally suitable for all scenarios. Here are some considerations:
Advantages of Non-Cycloplegic Refraction
- Binocular Vision Insights: Non-cycloplegic retinoscopy can provide insights into binocular vision functions, such as near lag of accommodation, which is not possible with cycloplegic refraction.
- Convenience and Accessibility: In settings where cycloplegic agents are not available or contraindicated, non-cycloplegic methods can serve as a.
- Fogging Techniques: Using contralateral fogging during non-cycloplegic retinoscopy can help relax accommodation, achieving results comparable to cycloplegic refraction within a certain margin of error.
Limitations of Non-Cycloplegic Refraction
- Accommodation-Induced Errors: Active accommodation can lead to inaccurate measurements, particularly in children, resulting in overestimation of myopia or underestimation of hyperopia.
- Variability in Results: Non-cycloplegic autorefraction tends to yield more myopic readings compared to cycloplegic autorefraction, which can lead to incorrect diagnoses or treatment plans.
- Age and Refractive Error Considerations: In younger children or those with high refractive errors, non-cycloplegic methods may not provide reliable results and should be confirmed with retinoscopy.

When Non-Cycloplegic Refraction May Be Sufficient
- Adults or Older Children: In cases where accommodation is less active, non-cycloplegic methods may be adequate for monitoring myopia progression.
- Low-Resource Settings: When cycloplegic agents are not available, non-cycloplegic techniques can be used as a fallback, though with caution regarding potential inaccuracies.
FAQ
1. Why is cycloplegic refraction important for myopia management?
Cycloplegic refraction provides an accurate measurement of refractive error by temporarily relaxing the eyeâs focusing muscles, helping to diagnose true myopia and differentiate it from pseudo-myopia.
2. How does biometry help in myopia management?
Biometry measures the axial length of the eye, allowing ophthalmologists to track myopia progression and adjust treatment strategies accordingly.
3. Is cycloplegic refraction necessary for children with myopia?
Yes, it is essential for children as their eyes have a strong ability to accommodate, which can lead to an inaccurate prescription if standard refraction is used.
4. How often should biometry and cycloplegic refraction be performed for myopia management?
It depends on individual cases, but typically, these tests should be done annually or bi-annually to monitor myopia progression effectively.
5. Can myopia be managed without biometry and cycloplegic refraction?
While basic eye exams help, skipping these tests may lead to inaccurate prescriptions and ineffective myopia control, increasing the risk of complications.
Conclusion
Both cycloplegic refraction and biometry are indispensable tools for precise myopia management. While cycloplegic refraction provides an accurate refractive assessment, biometry aids in monitoring myopia progression effectively. If you or your child is experiencing worsening myopia, consulting an experienced ophthalmologist at Aurobindo Eye Care And Health Center can help ensure optimal eye health and prevent future complications.